| Maximum number of served floors: |
• 16 full collective in classic wiring
• 24 down collective in classic wiring
• 48 full in serial wiring |
| |
|
| Maximum number of elevators working in group: |
• 8 |
| |
|
| Supported elevator systems: |
• electric two speed
• electric VVVF
• hydraulic |
| |
|
| Maximum elevator speed: |
• 4 m/s |
| |
|
| Positioning possibilities: |
• switches for shaft information
• switches for pre-opening
• switches for relevelling
• incremental pulses |
| |
|
| Number of doors served: |
• 2 |
| |
|
| Door types served: |
• all types |
| |
|
| User's interface: |
• built in 2 x seven-segment indicator
for position and malfunction display
• built in RS 232 line for programming
and supervision |
| |
|
| Real time clock: |
• yes |
| |
|
| Serial output for indicator and voice module: |
• 3 x line with SSL3 protocol |
| |
|
| Other important characteristics: |
• 25 programmable timers
• 195 programmable parameters
• 194 counters for statistics
• up to 200 errors in error table with time stamp
reduced cabling in the line shaft and to the car
all inputs equipped with LED diodes
• supervision and programming
trough RS232 line
• LCD programmer, PC or PDA for programming
special software LIFTS for supervision
• all connections made with plugs |
| |
|
| Compliance with standards: |
• EN 81-1
• EN 81-2
• EN 8 1 -70 (DDA)
• EN 81-72
• lift directive EC 95/ 1 6
• AS 1735.2
• EN 12015
• EN 12016
• EN 50178 |
| |
|
 |
|