| Maximum number of served floors: |
• 6 full collective
• 11 full collective with extension
• 9 down collective
• 15 down collective with extension
• 16 universal control |
| |
|
| Maximum number of elevators working in group: |
•2 |
| |
|
| Supported elevator systems: |
• electric VVVF hydraulic
• Maximum elevator speed: 1,5 m/s |
| |
|
| Positioning possibilities: |
• switches for shaft information
• switches for pre-opening
• switches for relevelling |
| |
|
| Number of doors served: |
•1 |
| |
|
| Door types served: |
• all types |
| |
|
| User's interface: |
• built in LED diode for position
indicator and error signalisation
• built in RS 232 line for programming. |
| |
|
| Serial output for indicator and voice module: |
• 1 x line with SSL2 protocol |
| |
|
| Other important characteristics: |
• 19 programmable timers
• 76 programmable parameters
• error table and last events table
in EEPROM circuit
• all inputs equipped with LED diodes
• all connections made with plugs |
| |
|
| Compliance with standards: |
• EN 81-1
• EN 81-2
• EN 81-72
• lift directive EC 95 /16
• AS 1735.2
• EN 12015
• EN 12016
• EN 50178 |
| |
|
 |
|